Moyno Pumps Operations and Maintanence

The Progressive Cavity Pump of a Moyno Pump is pretty standard to nearly all PC Pump manufacturers recommended standard procedure for starting this type of pumps. Number one rule when starting a Moyno Pump is making sure that all inlets and ourlets valves are opened and that we have fluid inside the suction housing of the pump; otherwise, we risk the notion of running the pump dry and is one of the biggest mistake when operation a Moyno Pump.

Moyno


Checklist When Starting a Moyno Pump

  1. Never run the progressive cavity pump dry. A few rotations in dry condition will damage the stator!
  2. Open valves and vents before starting the pump.
  3. Check the direction of rotation by briefly switching on the pump motor.